Modularity: rapid deployment, flexible architecture, on-demand upgrade, elastic expansion Each unit adopts a modular design and has independent functions, and has redundancy, backup and fault tolerance; the construction period can be shortened to 2~3 months, which can quickly respond to business needs; on-demand deployment, flexible scheduling, maximum protection of investment, Avoid over-planning, make it easier to scale, and run more economically.
Standardization: Standardize each unit to reduce production and operation and maintenance costs
Channels, cabinets, power supply and distribution units are factory prefabricated, standardized production, and cost reduction; interfaces between units, the engineering interface is clear, the construction is simple, pre-testing, on-site engineering, plug and play, quality control, reduce maintenance difficulty and operation and maintenance costs.
Green energy saving: PUE value is lower than that of traditional data centers, greatly reducing operating costs
High-efficiency modular UPS, closed hot and cold aisle, high-efficiency cooling, and high-density solutions are adopted, and the optimized PUE value is less than 1.2~1.5, which reduces energy consumption and greatly reduces operating costs.
Intelligent: all-round comprehensive monitoring, easy to manage
Centralized intelligent monitoring of power supply and distribution units (UPS, power distribution cabinets), refrigeration units (air conditioners), system environment, and system security (fire protection, access control), etc., can realize real-time monitoring, network hierarchical management, energy efficiency management, capacity management, Visual management, intelligent linkage security management and other functions, based on big data analysis, build a green and energy-saving data center.
Customization: to meet the special needs of users
According to the special needs of users and on-site conditions, we can provide customized solutions to achieve micro-module products that can be quickly deployed.
Adopt American Copeland high-efficiency scroll compressor with high efficiency, low noise and low energy consumption. Copeland Scroll's patented axial and radial Copeland flex design provides unprecedented resistance to liquid slam and impurities, ensuring a seal between the scrolls. Copeland Scroll compressors have a wide operating range with oil level test valve and crankcase heaters on all models. Copeland Scroll compressors ensure high performance ratioses, scrolls run in rather than wear, better performance with increased operating time, higher life and reliability. Copeland Scroll compressors are ideal for high reliability, high energy efficiency, compact system designs.
Product introduction
CMS series industrial-grade modular UPS power supply is a high-end modular UPS product introduced to the market following the new concept of "energy saving, green and environmental protection". It not only includes the rectification, filtering, charging, inverter of traditional UPS The device also has intelligent power protection function, and adopts many new concept technologies such as average current control rectification technology, sequential master-slave synchronous control technology, multi-level distributed control technology and third-order sine wave inverter. On the basis of greatly improving the availability and reliability of the equipment, the investment, operation and maintenance costs of the equipment are reduced.
Performance characteristics
■The system capacity has 50KVA, 100KVA, 150KVA, 250KVA, 350KVA, 500KVA, 800KVA series, the power module is 10KVA, 25KVA, 50KVA, three power ranges, the user can choose according to the load size;
■The system is a modular structure, consisting of a static switch module, a monitoring module and N power modules in parallel. The modules are N+X redundant and can be upgraded and expanded online according to user needs;
■Up to four systems can be used in parallel, meeting the requirements of N+1, 2N, Δ2N power supply schemes;
■Monitoring module, static switch module and power module can be hot-swapped online;
■The system can be set to 1/1, 1/3, 3/1 or 3/3 of the incoming and outgoing lines as needed;
■Adopt no master-slave parallel, multi-level distributed control technology, no running bottleneck and reliable performance;
■All power modules share battery pack;
■Have perfect battery management functions: battery self-discharge function, automatic floating charge conversion function, temperature compensation function, automatic current sharing function;
■Any power module has the function of balanced distribution of input, output and charging power;
■The efficiency of the whole machine is greater than 95% (AC-AC), the inverter efficiency is greater than 98% (DC-AC), and the input power factor (PF) is greater than 0.99;
■The AC input adopts continuous current mode (CCM) operation to reduce interference to the grid (RFI/EMI);
■The shape and structure meet the requirements of industry specifications, the equipment is small in size and light in weight, which can meet the load-bearing requirements of ordinary buildings;
■Optional input and output K value isolation transformer;
■Manual maintenance switch, RS232, RS485/RS422 communication interface, and remote monitoring software are standard configuration. Optional SNMP card, lightning protection module and input and output switches.
Application field
Communication, electricity, transportation, radio and television, finance, taxation, medical care, education, scientific research, enterprise, petrochemical, industrial and mining, etc.
Modularity: rapid deployment, flexible architecture, on-demand upgrade, elastic expansion Each unit adopts a modular design and has independent functions, and has redundancy, backup and fault tolerance; the construction period can be shortened to 2~3 months, which can quickly respond to business needs; on-demand deployment, flexible scheduling, maximum protection of investment, Avoid over-planning, make it easier to scale, and run more economically.
Standardization: Standardize each unit to reduce production and operation and maintenance costs
Channels, cabinets, power supply and distribution units are factory prefabricated, standardized production, and cost reduction; interfaces between units, the engineering interface is clear, the construction is simple, pre-testing, on-site engineering, plug and play, quality control, reduce maintenance difficulty and operation and maintenance costs.
Green energy saving: PUE value is lower than that of traditional data centers, greatly reducing operating costs
High-efficiency modular UPS, closed hot and cold aisle, high-efficiency cooling, and high-density solutions are adopted, and the optimized PUE value is less than 1.2~1.5, which reduces energy consumption and greatly reduces operating costs.
Intelligent: all-round comprehensive monitoring, easy to manage
Centralized intelligent monitoring of power supply and distribution units (UPS, power distribution cabinets), refrigeration units (air conditioners), system environment, and system security (fire protection, access control), etc., can realize real-time monitoring, network hierarchical management, energy efficiency management, capacity management, Visual management, intelligent linkage security management and other functions, based on big data analysis, build a green and energy-saving data center.
Customization: to meet the special needs of users
According to the special needs of users and on-site conditions, we can provide customized solutions to achieve micro-module products that can be quickly deployed.
Adopt American Copeland high-efficiency scroll compressor with high efficiency, low noise and low energy consumption. Copeland Scroll's patented axial and radial Copeland flex design provides unprecedented resistance to liquid slam and impurities, ensuring a seal between the scrolls. Copeland Scroll compressors have a wide operating range with oil level test valve and crankcase heaters on all models. Copeland Scroll compressors ensure high performance ratioses, scrolls run in rather than wear, better performance with increased operating time, higher life and reliability. Copeland Scroll compressors are ideal for high reliability, high energy efficiency, compact system designs.
Product introduction
CMS series industrial-grade modular UPS power supply is a high-end modular UPS product introduced to the market following the new concept of "energy saving, green and environmental protection". It not only includes the rectification, filtering, charging, inverter of traditional UPS The device also has intelligent power protection function, and adopts many new concept technologies such as average current control rectification technology, sequential master-slave synchronous control technology, multi-level distributed control technology and third-order sine wave inverter. On the basis of greatly improving the availability and reliability of the equipment, the investment, operation and maintenance costs of the equipment are reduced.
Performance characteristics
■The system capacity has 50KVA, 100KVA, 150KVA, 250KVA, 350KVA, 500KVA, 800KVA series, the power module is 10KVA, 25KVA, 50KVA, three power ranges, the user can choose according to the load size;
■The system is a modular structure, consisting of a static switch module, a monitoring module and N power modules in parallel. The modules are N+X redundant and can be upgraded and expanded online according to user needs;
■Up to four systems can be used in parallel, meeting the requirements of N+1, 2N, Δ2N power supply schemes;
■Monitoring module, static switch module and power module can be hot-swapped online;
■The system can be set to 1/1, 1/3, 3/1 or 3/3 of the incoming and outgoing lines as needed;
■Adopt no master-slave parallel, multi-level distributed control technology, no running bottleneck and reliable performance;
■All power modules share battery pack;
■Have perfect battery management functions: battery self-discharge function, automatic floating charge conversion function, temperature compensation function, automatic current sharing function;
■Any power module has the function of balanced distribution of input, output and charging power;
■The efficiency of the whole machine is greater than 95% (AC-AC), the inverter efficiency is greater than 98% (DC-AC), and the input power factor (PF) is greater than 0.99;
■The AC input adopts continuous current mode (CCM) operation to reduce interference to the grid (RFI/EMI);
■The shape and structure meet the requirements of industry specifications, the equipment is small in size and light in weight, which can meet the load-bearing requirements of ordinary buildings;
■Optional input and output K value isolation transformer;
■Manual maintenance switch, RS232, RS485/RS422 communication interface, and remote monitoring software are standard configuration. Optional SNMP card, lightning protection module and input and output switches.
Application field
Communication, electricity, transportation, radio and television, finance, taxation, medical care, education, scientific research, enterprise, petrochemical, industrial and mining, etc.
1 x PSRHH4802-Y-R 1 x PSRHH4502-Y-R 1 x PSRHH5103 1 x PSRHH5003.C-Y 1 x PSRHH9004.C-Y 3x PSRHH2401M
1 x FOCSWATER4102 3 x FOCSWATER6004C 3 x KMC800LH 3 x PSRHH6003C-R-Y
1 x KMC-1100LY-INV 1 x KMC1100LY 2 x KMC-1100LY-D 1 x CCS0500-INV 2 x CCS0500-INV 2 x FOCSWATER2501
3 x TECS-W4503L-E
2 x ERACS3622E-N-D-B 1 x ERACS3602E-N-B 2 x ERACS3622E-N-B 52 x MFC 900 x FCU